Hot / Cold Aisle

The Hot / Cold Aisle approach is considered to be the "norm" for data center designs. Racks are aligned front to front and cold air is delivered using the raised floor as a cold air handling space (plenum). The ANSI/TIA/ EIA-942-A (data center) standard recommends a cold aisle width of 1.2 metres (which is equivalent to two floor tiles) to allow a perforated tile to be placed in front of each cabinet which allows for cold air to be delivered to the cabinet front.

 

Racks are aligned front to front and cold air is delivered using the raised floor

Because the raised floor is being used to deliver the cold air it is essential that all openings within the floor, such as for the passage of cables, be sealed using a double brush grommet (DP-KP-KAR-A). This helps to maintain "static pressure" within the floor and minimises the amount of air that can escape the floor in unintended or undesired locations.


CONTEG test data shows a significant improvement to airflow in the case of 83% super-vented doors being used over standard perforated door types. In order to make the best use of available cold air it is recommended to blank-off any un-used space within the rack by using standard blank panels.

Keep your Data Center under full control with Aegis infrastructure management system

Additionally, using an air separation frame at the front of the rack will help to block unwanted cold air by-pass around the mounting profiles leading to an improvement in cooling efficiency for equipment that uses front to back airflow.
Door perforation Blank panels Separation frame

Recommended Hot / Cold aisle rack design

Front vented door allows the cold air to easily enter the rack whereas the rear vented door means that warm air is not trapped within the rack but exhausted into the hot aisle; it is recommended to use separation frames and blanking panels to optimize air-flow within the rack.

  • Front vented door (83% perforation rate) with multipoint swivel handle lock
  • Rear vented door (83% perforation rate) with multipoint swivel handle lock
  • Removable sheet steel side panels with lock
  • Two pairs of 19" vertical sliding extrusions
  • Top and bottom openings for cable entry; removable top plate (only RDF racks)
  • Adjustable feet as standard; recommended plinth or plinth with filter

When racks cannot be used for any reason, there is always an alternative - 19" highload open frames RSG4. Load rating is up to 1200kg, they are suitable also for installation of heavy servers, disk arrays etc. The frames are also suitable for use in testing and service rooms.


Data Center Cooling

Hot/Cold aisle deployments are ideally suited to deployments which utilise central room cooling with locally positioned close control units. Since 2008, CONTEG is an official partner of the global leader in precision cooling. Please, feel free to contact us. We will be glad to help you, together with our colleagues, with your project whatever it is a project requiring simple cooling solution or an enormous central cooling capacity. Read More

Datacenter and server room CFD modeling services

Computational Fluid Dynamics (CFD) modeling is a technical service designed to provide the detailed data to assess and track the temperature and air flow within your existing or proposed data center, server room or main equipment room.Working with your design team the Conteg team of specialists will assist in the space planning and layout, then model your project. The CFD model will simulate the air flows, air pressures and temperature maps for your data center or server room project. Read More



Aegis Data center infrastructure management

The CONTEG Aegis Data Center infrastructure management (DCMS) is a complete monitoring application for managing the entire data center infrastructure. CONTEG Aegis infrastructure management system collects, analyses and reports all the necessary information in real-time using standardized data communication protocols. Read More


Product / project Support:
When preparing a complex network project, consultants, designers or the end user IT department can benefit from the advice or support of our product managers. Incorrect estimation of the requirements for a project, whether under-sizing an air-conditioning system or simply failing to allow adequate space for cable management, can have a drastic impact on the reliability of the installed equipment and the functionality of the facility as a whole.


With our product managers´support you will be able to select the most suitable rack type for installation of any instrumentation, its power supply, cooling or just maybe only the correct system of cable management.


Related products Description
ROF series 19" distribution racks Traditional and proven rack series - highly configurable
RHF series 19" distribution racks High-load racks with load rating up to 1500kg - dedicated for housing heavy devices
Cable entries Cable entry products for easy throughput of cables without air pressure losses
Blank panels Prevent cold air by-pass through unused U positions
In-row Cooling Units Very high density heat loads with cooling capacity up to 34kW
Modular plinths Replace adjustable feet and are used as stabilizing and aesthetic element
Power Distributions Units For high density power within the data centre and server room environment
Separation frame Used for minimizing by-pass airflow between columns and extrusions
Space optimalisation sections
To help achieve the most effective use of available floor space within the data center

Go on to: 

More information needed?
Contact us with confidence and allow us to show you how our extensive knowledge can support you in the design and specification of your facility.

Download the materials available or contact us using the query form.