Side mount cooling units

Conteg Side Mount Cooling can be deployed in the cabinet row to deliver cooling directly to the cold-aisle. The units are connected to the central chilled water system, (or moto-condensers in the case of DX units) and control the temperature and humidity of the output air. For optimum efficiency combine side mount chillers with a contained cold aisle system to trap the cold air produced. Piping for the side mount units can be laid in advance and then the units added as the facility is built out thus saving initial infrastructure investment costs.

Architecture with an open air circuit
The Side Open Architecture system is ideally suited for use in hot/cold and contained cold aisle deployments and can be used to supplement the existing cooling system within a facility to add capacity on a zone by zone basis. Warm air is drawn directly from the hot aisle, cooled and humidified by the side mounted cooling units before being blown back into the cold aisle for use by equipment.

Architecture with a closed air circuit
Ideally suited for very high heat density racks where traditionally delivered cooling air may not provide sufficient capacity. Additionally, the side mount closed architecture ensures that heat generated within the cabinet is removed at the point of production and not released into the data center environment, thereby minimizing the chances of localized hot-spots forming in the high density zones.

  • Cooling capacities: up to 36kW; even the most demanding computing equipment can be kept at the optimum temperature
  • Height: 42, 45 or 48U
  • Width: 300mm
  • Depth: 1000 or 1200mm (1000mm not applicable for closed loop)
  • Available in Direct Expansion (DX) and Chilled Water (CW) variants
  • Plumbed to either outdoor micro-condensers or the central chilled water systems. Pipes are laid below raised floor and routed to the chilled water or micro-condenser installations
  • EC fans available upon request
Cooling units with open architecture are compatible with free-standing racks of the ROF, RHF, RDF, RMF, RSL, ROS and REV series. Compatibility of the side mount cooling units with closed architecture will be communicated upon request.

CONTEG Contained Aisle System
The Side Open Architecture system is ideally suited for use in hot/cold aisle deployments and can be used to supplement the existing cooling system within a facility to add capacity on a zone by zone basis. Warm air is drawn directly from the hot aisle, cooled and humidified by the side mounted cooling units before being blown back into the cold aisle for use by equipment. The range of available capacities mean that it is now easy to tailor zone cooling requirements in a hot/cold aisle deployment without over-cooling the entire facility. Furthermore, side cooling can be combined with the Conteg contained cold-aisle solution as shown below to further promote efficient use of chilled air leading to reduced facility operational costs. For more information, please go to Contained Aisle System

CONTEG Cold Aisle Containment - top view

 

 

 

 

 

 

In order to provide remote monitoring and a possibility of alarm status information, we recommend combining the side mount cooling units with a racks monitoring system. More information can be found here:

 